Concrete Shelter
Self-weight · Elastic concrete · Fixed bases How does widening or shifting the rear window change the way the roof is supported?
Generate drawings with .venv/bin/python website/build_data.py --plans-only.
Deflections are measured at the floor and roof slab corners and above the door. Glazing is shown for context. Glazing movement allowance depends on the relative movement between its supports.
The geometry shows the full canopy. The analysis focuses on the wall anchorage under the tie-rod load. The table shows calculated tension and shear forces for each bolt.
The pale slab extension and neighbouring column show where the local model sits in a floor bay.
Load transfer around the column
The table reports the share of vertical shear crossing each side of the cut. The violet dashes mark its east side, towards the opening.
| Side of study cut | Share of shear |
|---|
Local vertical shear stress · 0 to 0.50 MPa. Interpolated colours show where shear concentrates. Local peaks depend on mesh size.
Blue outlines the service opening. Values in parentheses are changes in percentage points from the slab without an opening.
Model assumptions
Linear-elastic 3D concrete solids. The same 300 kN is distributed over the available slab surface in each variant. The cut is a fixed 1 m square. The shares come from the integrated vertical forces crossing the cut. Loads applied inside that square go to the column without crossing the cut.
The study shows shear redistribution. A punching resistance check would also account for reinforcement, cracking and failure.
Window opening at the cantilever root
Dashed grey is the original opening. The orange diagonals are measurement lines. Window deformation is shown ×60 and building deformation ×20. All reported movements are actual model values.
Model assumptions
A linear 3D beam FEM represents the two steel Vierendeel frames and their transverse floor beams. The core is fixed. Illustrative floor loads are distributed 70% to the near facade and 30% to the far facade. The semi-rigid option adds 90 MN·m/rad rotational springs at the post ends in the facade plane. Slabs and the core volume are shown for context.
The treated room adds absorptive panels to the ceiling and rear wall. Both clips use the same speaker and seat.
Model assumptions
A centreline image-source model traces first-order specular reflections. The synthetic voice is filtered in three frequency bands. Surface absorption affects both early reflections and a diffuse reverberation tail. Audio illustrates relative changes across variants.
| Construction stage | Differential settlement |
|---|
Point A (blue) is outside the excavation. Point B (red) is above the gallery centre. Settlements are measured relative to the existing condition. Deformed geometry is amplified ×35 throughout.
Model assumptions
The existing facade is represented by its line load on a beam foundation. An Euler–Bernoulli finite element model on linear springs represents the ground, the temporary props and the permanent walls. The permanent transfer beam is activated in the excavated configuration. Ground stiffness and support properties are illustrative.
Static hanger removal
Both cases use the same deck load. The violet ring marks the removed hanger’s deck anchorage.
| Result | Intact | Hanger removed |
|---|
Glazing is modelled as distributed weight on the steel frame. Slit closure is the largest reduction in width between the two steel edges under self-weight.
Indoor air temperature over three hot days
Illustrative clear-sky summer days at Lausanne latitude. Times are local solar time. The cabin has no active cooling and uses a fixed ventilation rate of 0.55 air changes per hour.
Elmer solves transient one-dimensional conduction through the envelope coupled to a well-mixed indoor-air node. The 3D view colours each face by a single value. Solar exposure shows incident irradiance before shading, while the solar gain readout includes the glazing and louvres.
Vertical acceleration at the outer walking edge
Elmer solves for the steady-state response to a fixed 180 N sinusoidal footfall patch. The deck ends are fixed and the hanger is a vertical spring with axial stiffness EA/L. The glass and steel guardrails add distributed mass to the deck. The landings and hanger terminals provide visual context. Deck Rayleigh damping is calibrated to 2% at 2 and 12 Hz.
The animation shows one cycle slowed down, with exaggerated movement. Blue is upward and ochre is downward. This comparison uses an illustrative load and damping.
Where does the slab start to crack?
Slab self-weight, railing weight along the curved edge and a uniform 4 kPa study load. Cantilever strips estimate where the cracking moment is exceeded. Elmer shell elements use a local effective modulus based on the top reinforcement. The same first-cracking criterion applies to both layouts.
The support is fixed. The railing contributes weight only. Reinforcement is represented through section stiffness. This study covers short-term deflection under the illustrated load.
Concrete volume optimisation
- Variables. Each height band shares two design variables across all its storeys: core wall thickness and shear wall thickness.
- Fixed inputs. storeys, mm slabs, fixed base, self-weight and illustrative wind.
- Constraints. Wall thicknesses of and interstorey drift of at most .
Minimise V(t) = Vslabs + Σj=1…6 Ajtj
Check drift maxi |ui(t) − ui−1(t)| / hi ≤
Aj is the wall centreline area. ui is the floor-average lateral displacement from Elmer. hi is the storey height.
| Band | Storeys | Core | Shear walls |
|---|
Elmer evaluations
| Bolt position | Axial force (kN) | Shear force (kN) |
|---|